• DocumentCode
    1007779
  • Title

    Results of the test of the European LCT coil in the TOSKA facility

  • Author

    Herz, W. ; Katheder, H. ; Krauth, H. ; Nöther, G. ; Padligur, U. ; Rietzschel, K. ; Siewerdt, L. ; Susser, M. ; Ulbricht, A. ; Wuchner, F. ; Zahn, G.

  • Author_Institution
    Kernforschungszentrum Karlsruhe, Karlsruhe, F.R. Germany
  • Volume
    21
  • Issue
    2
  • fYear
    1985
  • fDate
    3/1/1985 12:00:00 AM
  • Firstpage
    249
  • Lastpage
    252
  • Abstract
    The forced flow cooled European LCT coil was tested successfully as a single coil in the Karlsruhe test facility TOSKA. Operation at design conditions (10 kA, 5.6 T at 4.8 K and 6 bar) was achieved without any problems. Cryogenic, mechanical and electrical performance was in agreement with predictions. Due to the high stability, the coil could be operated close to its critical parameters by heating the supercritical helium up to about 6 K. The coil stayed superconducting even after a fast dump (7 s) from full current. Good performance is also expected for operation in the 6 coil toroidal array of the LCTF.
  • Keywords
    Superconducting coils; Conductors; Cryogenics; Helium; Stability; Strain measurement; Stress; Superconducting coils; Superconducting magnets; Temperature sensors; Testing;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/TMAG.1985.1063611
  • Filename
    1063611