DocumentCode :
1007960
Title :
Spark Lag of the Sphere Gap
Author :
Tilles, Abe
Author_Institution :
Univ. of California, Berkeley.
Volume :
54
Issue :
8
fYear :
1935
Firstpage :
868
Lastpage :
876
Abstract :
Measurements of time lag of spark-over of small sphere gaps at 3,820 volts were made with an instrument developed specifically for the purpose. Spark lags were found to fall into 3 distinct domains: 1 of relatively long initiatory lags of random distribution, and 2 of definite formative lags of different orders of magnitude corresponding to 2 different spark-over mechanisms. The controlling conditions which determine into which domain the spark lag will fall are given. The manner in which this lag may obscure the sparking voltage of the gap is pointed out and a remedial specification suggested. The results are applicable to larger sphere gaps and higher voltages.
Keywords :
Breakdown voltage; Diesel engines; Internal combustion engines; Machinery; Rail transportation; Railway engineering; Sparks; Time measurement;
fLanguage :
English
Journal_Title :
American Institute of Electrical Engineers, Transactions of the
Publisher :
ieee
ISSN :
0096-3860
Type :
jour
DOI :
10.1109/T-AIEE.1935.5057093
Filename :
5057093
Link To Document :
بازگشت