Prototype design, construction and test of a Pb/scintillator sampling calorimeter with wavelength shifter fiber optic readout
Author
Benvenuti, A. ; Giordano, V. ; Guerzoni, M. ; Navarri, F.L. ; Camporesi, T. ; Vaz, P. ; Alvsvaag, S.J. ; Maeland, O.A. ; Klovning, A. ; Rongved, R. ; Read, A.L. ; Bjarne, J. ; Hedberg, V. ; Jarlskog, G. ; Kronkvis, L. ; Cassio, V. ; Gamba, Davide ; Torass
Author_Institution
INFN, Bologna Univ., Italy
Volume
40
Issue
4
fYear
1993
fDate
8/1/1993 12:00:00 AM
Firstpage
537
Lastpage
545
Abstract
A prototype for the new DELPHI luminosity monitor has been built and tested. The scope of this prototype is to measure the response of the proposed calorimeter in the region which is most critical for the luminosity measurement, i.e., at the inner edge of the acceptance. The aim of the new luminosity monitor is to measure the LEP (Large Electron Position Collider) luminosity with per mill systematic uncertainty. This requires experimental biases at the level of 50 μm or less in the definition of the fiducial volume. The technique used ensures good energy resolution and high spatial uniformity. With the prototype, better than 2% uniformity in response and an energy resolution of 3% at 45 GeV have been achieved
Keywords
calorimeters; scintillation counters; 45 GeV; 50 micron; DELPHI luminosity monitor; Pb/scintillator sampling calorimeter; construction; design; energy resolution; fiducial volume; spatial uniformity; wavelength shifter fiber optic readout; Detectors; Energy resolution; Monitoring; Optical design; Optical fiber testing; Optical fibers; Poles and towers; Prototypes; Sampling methods; Tiles;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/23.256612
Filename
256612
Link To Document