Abstract :
The performance of a 128-channel test module made with straw tubes of 2-mm radius was studied in a test beam and with cosmic rays. Different gases were used, and for each one the time-to-distance relation and the hit efficiency were measured. Comparisons are made between results obtained using two different electronics readouts. The best solution, of 135 μm, was obtained using 50% ethane, 50% argon and reading out the information with the TDCs (time-to-digital converters), at an operating voltage of 1750 V
Keywords :
position sensitive particle detectors; radiation detection and measurement; 135 micron; 1750 V; 2 mm; Ar ethane mixture; TDCs; cosmic rays; hit efficiency; readout; straw tube drift cells; time-to-digital converters; time-to-distance relation; Aluminum; Cosmic rays; Counting circuits; Detectors; Gases; Laboratories; Structural beams; Testing; Voltage; Wires;