Title :
Induction Motors Under Unblanced Conditions
Author_Institution :
University of British Columbia, Vancouver; Peterson and Cowan Elevator Co. Ltd., Vancouver, B. C.
fDate :
4/1/1936 12:00:00 AM
Abstract :
A general equation (17) for the output of an induction motor operating under unbalanced conditions of applied voltage and primary and secondary impedance, is deduced in terms of frequency of applied voltage, slip, and rotor copper losses, General equations for the currents flowing in the windings are given in appendix I, from which the secondary copper losses, and hence the output and torque, may be calculated. Special conditions of partial unbalance also are considered.
Keywords :
Cable shielding; Circuit faults; Conductors; Impedance measurement; Induction motors; Power cables; Power measurement; Substations; Underground power cables;
Journal_Title :
American Institute of Electrical Engineers, Transactions of the
DOI :
10.1109/T-AIEE.1936.5057278