DocumentCode
1010735
Title
Heater-Cathode Insulation Performance
Author
Klemperer, Hans
Author_Institution
Westinghouse Elec. and Mfg. Co., East Pittsburgh, Pa.
Volume
55
Issue
9
fYear
1936
Firstpage
981
Lastpage
985
Abstract
The insulation between the heater wire and the cathode of electronic tubes of the indirectly heated cathode type is required to conduct heat while maintaining high electrical resistance at operating temperatures. By means of cathode-ray oscillograms the effects of operating temperature, heat treatment, and impurities upon the electrical conduction of the commonly used insulating materials are shown in this paper.