• DocumentCode
    1012220
  • Title

    The influence of the internal correction voltage on the proper ratings of receiving-type tubes

  • Author

    Neill, George D O

  • Author_Institution
    Sylvania Res. Labs., Bayside, N. Y.
  • Volume
    5
  • Issue
    2
  • fYear
    1958
  • fDate
    4/1/1958 12:00:00 AM
  • Firstpage
    69
  • Lastpage
    75
  • Abstract
    Uncertainties in establishing rated values for the low-frequency characteristics of receiving-type tubes are discussed, and it is shown that when a measure of the internal correction voltage is ascertained by the use of generally available data, the problem is greatly simplified. The method of applying it in properly rating the characteristics is described. The nature of the correction voltage is briefly outlined in a manner intended to be helpful in problems of design and quality control.
  • Keywords
    Cathodes; Character recognition; Contacts; Diodes; Electrodes; Electron devices; Electron emission; Electron tubes; Industrial relations; Quality control; Standardization; Transconductance; Voltage;
  • fLanguage
    English
  • Journal_Title
    Electron Devices, IRE Transactions on
  • Publisher
    ieee
  • ISSN
    0096-2430
  • Type

    jour

  • DOI
    10.1109/T-ED.1958.14335
  • Filename
    1472378