Title :
Frequency instability measurement system of cryogenic maser oscillator
Author :
Benmessai, K. ; Bourgeois, P.Y. ; Kersalé, Y. ; Bazin, N. ; Tobar, M.E. ; Hartnett, J.G. ; Oxborrow, M. ; Giordano, V.
Author_Institution :
Univ. de Franche-Comte, Besancon
Abstract :
The frequency stability measurement of a new kind of secondary frequency standard, the whispering gallery mode maser oscillator, is reported. Based on a very simple design the beatnote comparison with a state-of-the-art cryogenic sapphire resonator oscillator gave a preliminary result of 10-14 frequency instability at 1 s integration time. The measurement is limited by the microwave synthesis chain used to evaluate the maser stability.
Keywords :
cryogenic electronics; frequency stability; masers; oscillators; whispering gallery modes; cryogenic maser oscillator; frequency instability measurement system; secondary frequency standard; whispering gallery mode maser oscillator;
Journal_Title :
Electronics Letters
DOI :
10.1049/el:20072684