DocumentCode
1016306
Title
A high frequency core loss automatic measuring system
Author
Mochizuki, T. ; Sasaki, I. ; Murakawa, K.
Author_Institution
Fuji Electrochemical Company, Ltd. Kosai, Shizuoka, Japan
Volume
22
Issue
5
fYear
1986
fDate
9/1/1986 12:00:00 AM
Firstpage
668
Lastpage
670
Abstract
A high frequency core loss automatic measuring system is developed by using a waveform memory device and a micro-computer. Sample, temperature, frequency and measuring level are changed automatically. This system can measure core loss, B-H characteristics and amplitude permeability for 20 samples in the frequency range up to 1 MHz. A required time of one experimental point is about 20 seconds from setting level within 5 % error to displaying B-H curve and results. The measured results show a good agreement with the results of multiplying voltmeter method.
Keywords
Magnetic measurements; Core loss; Frequency measurement; Loss measurement; Microcomputers; Permeability measurement; Power amplifiers; Power supplies; Radiofrequency amplifiers; Temperature measurement; Voltage;