DocumentCode :
1017520
Title :
A New High-Speed Thermal Wattmeter
Author :
Miller, John H.
Author_Institution :
Assistant chief engineer of the Weston Electrical Instrument Corporation, Newark, N. J.
Volume :
60
Issue :
1
fYear :
1941
Firstpage :
37
Lastpage :
40
Abstract :
The thermal converter discussed in this paper is of the type which produces at its output terminals a millivoltage proportional to the polyphase power connected to its input terminals, the connections being made as for a wattmeter. High-speed response is secured through the use of a new circuit network wherein the thermocouples function also as heaters. Response time of the order of one-half second is obtained. The use of nickel-alloy transformer cores saturating at overloads broadens the over-load capacity of the thermal unit itself. Thermal converters of this type are widely used in the summation of power.
Keywords :
Circuits; Current measurement; Current transformers; Frequency measurement; Heat engines; Instruments; Power measurement; Resistance heating; Temperature; Wattmeters;
fLanguage :
English
Journal_Title :
American Institute of Electrical Engineers, Transactions of the
Publisher :
ieee
ISSN :
0096-3860
Type :
jour
DOI :
10.1109/T-AIEE.1941.5058196
Filename :
5058196