    Testing of Elevator Buffers by Electrical Means

  • Author

    Kimberly, E.E.

  • Author_Institution
    Associate professor of electrical engineering, Ohio State University, Columbus.
  • Volume
    60
  • Issue
    2
  • fYear
    1941
  • Firstpage
    53
  • Lastpage
    54
  • Abstract
    The curves of figure 5 are typical of those obtainable by the electrical apparatus described. Inasmuch as the oil-pressure indicator was connected to the bottom of the buffer cylinder, there was a short time interval between the instant of maximum pressure as shown on the pressure gauge and the maximum deceleration. This time interval is that required for the high-pressure wave to travel through the oil from the piston to the gauge. This difference in time demonstrates the elasticity of the light transformer oil used. The accuracy of this method is satisfactory for all existing test codes.
  • Keywords
    Circuits; Coils; Elevators; Iron; Magnetic flux; Petroleum; Pistons; Power system harmonics; Testing; Voltage;