DocumentCode :
1020008
Title :
Accuracy check of TOSCA using a sectoral magnet with saturated iron poles
Author :
Kitamura, M. ; Tomeoku, H. ; Kobayashi, T. ; Maki, N. ; Nakata, J.
Author_Institution :
Hitachi Ltd., Ibaraki, Japan
Volume :
26
Issue :
2
fYear :
1990
fDate :
3/1/1990 12:00:00 AM
Firstpage :
909
Lastpage :
912
Abstract :
The calculation accuracy of TOSCA was examined using the 180° sectoral H-shaped dipole magnet model with a maximum field of 2.3 T and strongly saturated iron poles. The measured magnetic field uniformities in the gap between the saturated iron poles agreed with those calculated by TOSCA within the order of 10-3. When the central magnetic field of the dipole magnet model was low, good agreements within the order of 10-4 were obtained. The measured magnetic fields in the additional iron yoke placed close to the end of the dipole magnet model were also compared to TOSCA calculations. The agreements were within about 20%
Keywords :
physics computing; superconducting magnets; TOSCA; iron yoke; sectoral H-shaped dipole magnet model; strongly saturated iron poles; Accuracy; Copper; Iron; Laboratories; Magnetic field measurement; Magnetic sensors; Magnetostatics; Saturation magnetization; Superconducting coils; Superconducting magnets;
fLanguage :
English
Journal_Title :
Magnetics, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/20.106465
Filename :
106465
Link To Document :