DocumentCode
1020434
Title
Hot-Spot Winding Temperatures in Self-Cooled Oil-Insulated Transformers
Author
Vogel, F.J. ; Narbutovskih, Paul
Author_Institution
Division engineer, Westinghouse Electric and Manufacturing Company, Sharon, Pa.
Volume
61
Issue
3
fYear
1942
fDate
3/1/1942 12:00:00 AM
Firstpage
133
Lastpage
136
Abstract
A more accurate method than previously used for calculating temperature rises in transformers has been derived, and applied both to steady and transient conditions. This latter application, along with the recognition that newer transformers have both lower gradients and better oil protection, give the possibility of recommending much higher emergency loads than previously given to such apparatus.
Keywords
Copper; Iron; Low voltage; Oil insulation; Petroleum; TV; Temperature; Testing; Transformers; Viscosity;
fLanguage
English
Journal_Title
American Institute of Electrical Engineers, Transactions of the
Publisher
ieee
ISSN
0096-3860
Type
jour
DOI
10.1109/T-AIEE.1942.5058498