DocumentCode :
1020589
Title :
Insulator damage in high current discharges
Author :
Ranon, P.M. ; Kristiansen, M. ; Lehr, F.M. ; Hatfield, L.L.
Author_Institution :
Texas Tech University, Lubbock, Texas
Volume :
22
Issue :
6
fYear :
1986
fDate :
11/1/1986 12:00:00 AM
Firstpage :
1695
Lastpage :
1698
Abstract :
The results of ongoing insulator performance tests are reported. Various insulator materials were subjected to high current discharges on the order of 2 × 105Amperes with a pulse repetition rate on the order of one pulse every 7 seconds in atmospheric air. Insulator samples were inserted into a Surface Discharge Switch (SDS), with a ringing discharge of 435 kHz and approximately 90% reversal, for increased charge transport. The voltage hold-off strength and the cold voltage recovery are reported.
Keywords :
Insulator testing; Plastic insulators; Surface discharges; Boron; Degradation; Electric shock; Insulation; Physics; Rails; Surface discharges; Switches; Temperature; Voltage;