DocumentCode
1021316
Title
Maximum Induced Voltage between Coaxial Coils
Author
Caffey, Thurlow W.H.
Author_Institution
Sandia Laboratories, Albuquerque, NM.
Volume
16
Issue
4
fYear
1978
Firstpage
314
Lastpage
315
Abstract
The use of two coaxial coils, whose winding planes are horizontal, for signaling between a surface coil and a coil within the earth is well known. Simple formulas are given for the maximum induced voltage and the frequency at which the maximum occurs. The formulas apply to many combinations of soil conductivity and dielectric constant and are accurate to within ten percent.
Keywords
Coaxial components; Coils; Computer errors; Conductivity; Dielectric constant; Earth; Frequency estimation; Geoscience; Soil; Voltage;
fLanguage
English
Journal_Title
Geoscience Electronics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9413
Type
jour
DOI
10.1109/TGE.1978.294590
Filename
4071943
Link To Document