DocumentCode :
1022198
Title :
Testing of the pool-boiling cooled Japanese LCT coil in the international fusion superconducting magnet test facility
Author :
Okuno, K. ; Kato, T. ; Koizumi, K. ; Tsuji, H. ; Hiyama, T. ; Shimamoto, S. ; Hattori, Y. ; Kamiya, Shinichiro ; Mukai, H. ; Iida, Fumiya
Author_Institution :
Atomic Energy Research Institute, Ibaraki-ken, Japan.
Volume :
23
Issue :
2
fYear :
1987
fDate :
3/1/1987 12:00:00 AM
Firstpage :
1683
Lastpage :
1686
Abstract :
The Japanese LCT coil has successfully achieved the design field of 8 T in the toroidal array of the six LCT coils. In March, 1986, tests of the LCT coils were started following the cooldown of the whole facility. In the single-coil test and design-point test, in which the maximum field was 6.4 T and 8.1 T, respectively, the coil was charged, discharged, and dumped under different conditions. A recovery test and a simulated nuclear heating test were performed to investigate the stability of the coil. Measurements of displacement under the several conditions of electromagnetic load were analyzed to explain the mechanical behavior of the coil. Results obtained in the tests are reported in this paper.
Keywords :
Japan; Tokamaks, superconducting magnets; Displacement measurement; Heat recovery; Magnetic field measurement; Mechanical variables measurement; Performance evaluation; Stability; Superconducting coils; Superconducting magnets; Test facilities; Testing;
fLanguage :
English
Journal_Title :
Magnetics, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/TMAG.1987.1064837
Filename :
1064837
Link To Document :
بازگشت