Title :
Limit to sensitivity of optical fibre magnetometers due to shape anisotropy
Author :
Willson, J.P. ; Hale, P.G.
Author_Institution :
Standard Telecommunication Laboratories Limited, Harlow, UK
Abstract :
Shape anisotropy, or the demagnetising effect, limits the sensitivity achievable with optical fibre magnetometers. The optimum sensor geometry has the minimum cross-section compatible with efficient strain transfer. For a sensor head with multiple passes of magnetically sensitised fibre, there is a limit to the increase in sensitivity as the number of passes is increased.
Keywords :
fibre optic sensors; magneto-optical effects; magnetometers; demagnetising effect; limit to sensitivity; minimum cross-section; multiple passes of magnetically sensitised fibre; optical fibre magnetometers; optimum sensor geometry; sensitivity achievable; sensor head; shape anisotropy; strain transfer;
Journal_Title :
Electronics Letters
DOI :
10.1049/el:19860386