DocumentCode :
1023227
Title :
Temporal skew and mode conversion management in differential pairs to 15 GHz
Author :
Burford, M.R. ; Levin, P.A. ; Kazmierski, T.J.
Author_Institution :
Univ. of Southampton, Southampton
Volume :
44
Issue :
1
fYear :
2008
Firstpage :
35
Lastpage :
37
Abstract :
When used with emerging data-rates of 10 GHz and above, some standard transmission line length matching methods are shown to make mode conversion worse than without length matching. A new methodology for temporal skew management to preserve signal integrity in differential microstrip pairs to 15 GHz is proposed and validated through simulation.
Keywords :
microstrip lines; transmission line theory; differential microstrip pairs; frequency 15 GHz; signal integrity; temporal skew-mode conversion management; transmission line length matching methods;
fLanguage :
English
Journal_Title :
Electronics Letters
Publisher :
iet
ISSN :
0013-5194
Type :
jour
DOI :
10.1049/el:20082220
Filename :
4415015