• DocumentCode
    1025860
  • Title

    Low voltage firing characteristics of a triggered vacuum gap

  • Author

    Farrall, G.A.

  • Author_Institution
    General Electric Research Laboratory, Schenectady, N. Y.
  • Issue
    4
  • fYear
    1966
  • fDate
    4/1/1966 12:00:00 AM
  • Firstpage
    432
  • Lastpage
    438
  • Abstract
    The triggered vacuum gap is a normally nonconducting device in which a high-current metal-vapor arc can be established by a suitable pulse of current to a triggering electrode. While this gap is well suited to switching applications at high voltage, it has properties which make it useful at low voltage as well. The operation of the triggered vacuum gap has, therefore, been studied in the range 100 to 1000 volts. It was found that, although the gap could be triggered with currents as low as 0.02 amperes, consistent triggering with firing delays less than a microsecond required trigger pulses of 10 amperes or more. Little or no dependence of firing time on main gap voltage was observed. Below a few hundred volts, however, the probability of establishing a stable main discharge with a short duration trigger pulse falls off rapidly with decreasing gap voltage. The polarity of the main gap voltage and of the trigger pulse strongly influenced the firing characteristics of the gap in the range studied. These effects are discussed in detail.
  • fLanguage
    English
  • Journal_Title
    Electron Devices, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9383
  • Type

    jour

  • DOI
    10.1109/T-ED.1966.15707
  • Filename