Title :
Zero-voltage-switching half-bridge DC-DC converter with modified PWM control method
Author :
Mao, Hong ; Abu-Qahouq, Jaber ; Luo, Shiguo ; Batarseh, Issa
Author_Institution :
Sch. of Electr. Eng. & Comput. Sci., Univ. of Central Florida, Orlando, USA
fDate :
7/1/2004 12:00:00 AM
Abstract :
Asymmetric control scheme is an approach to achieve zero-voltage switching (ZVS) for half-bridge isolated dc-dc converters. However, it is not suited for wide range of input voltage due to the uneven voltage and current components stresses. This paper presents a novel "duty-cycle-shifted pulse-width modulated" (DCS PWM) control scheme for half-bridge isolated dc-dc converters to achieve ZVS operation for one of the two switches without causing the asymmetric penalties in the asymmetric control and without adding additional components. Based on the DCS PWM control scheme, an active-clamp branch comprising an auxiliary switch and a diode is added across the isolation transformer primary winding in the half-bridge converter to achieve ZVS for the other main switch by utilizing energy stored in the transformer leakage inductance. Moreover, the auxiliary switch also operates at ZVS and zero-current switching (ZCS) conditions. Furthermore, during the off-time period, the ringing resulted from the oscillation between the transformer leakage inductance and the junction capacitance of two switches is eliminated owing to the active-clamp branch and DCS PWM control scheme. Hence, switching losses and leakage-inductance-related losses are significantly reduced, which provides the converter with the potential to operate at higher efficiencies and higher switching frequencies. The principle of operation and key features of the proposed DCS PWM control scheme and two ZVS half-bridge topologies are illustrated and experimentally verified.
Keywords :
DC-DC power convertors; MOSFET; PWM power convertors; leakage currents; switching convertors; DCS PWM control scheme; MOSFET; active-clamp branch; asymmetric control scheme; current stress; duty-cycle-shifted pulse-width modulated control scheme; metal oxide semiconductor field effect transistors; modified PWM control methods; transformer leakage inductance; transformer primary winding; voltage stress; zero-current switching; zero-voltage-switching half-bridge DC-DC converters; DC-DC power converters; Distributed control; Inductance; Pulse width modulation; Pulse width modulation converters; Stress; Switches; Switching converters; Zero current switching; Zero voltage switching; DCS; Duty-cycle-shifted; HB; MOSFETs; PWM; ZCS; ZVS; half bridge; metal oxide semiconductor field effect transistors; pulse-width modulated; zero-current switching; zero-voltage switching;
Journal_Title :
Power Electronics, IEEE Transactions on
DOI :
10.1109/TPEL.2004.830052