DocumentCode :
1027368
Title :
Quality control of Rutherford-type cables by the eddy-current test method
Author :
Salathé, D. ; Maix, R.K.
Author_Institution :
BBC Brown Boveri Ltd., Zurich, Switzerland
Volume :
24
Issue :
2
fYear :
1988
fDate :
3/1/1988 12:00:00 AM
Firstpage :
1134
Lastpage :
1137
Abstract :
An eddy-current testing technique is reported that was used to detect defects in the flat Rutherford-type cable of the HERA (Hadron Electron Ring Accelerator) dipole magnets. Test results are presented that show the technique was able to find such defects as broken wires due to mechanical overload during cabling and rolling processes, and cross overs due to cold-weld.
Keywords :
eddy current testing; electron ring accelerators; flaw detection; particle accelerator accessories; quality control; superconducting magnets; Hadron Electron Ring Accelerator; Rutherford-type cables; broken wires; cold-weld; cross overs; defect detection; dipole magnets; eddy-current test method; mechanical overload; quality control; Bars; Fabrication; Production; Quality control; Solids; Superconducting cables; Surface cracks; Tellurium; Testing; Wires;
fLanguage :
English
Journal_Title :
Magnetics, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/20.11431
Filename :
11431
Link To Document :