• DocumentCode
    1027476
  • Title

    Transformer Noise Reduction witk a Close-Fitting Mass-Law Enclosure

  • Author

    Adkins, P.N.

  • Author_Institution
    Portland General Electric Company
  • Volume
    82
  • Issue
    66
  • fYear
    1963
  • fDate
    6/1/1963 12:00:00 AM
  • Firstpage
    302
  • Lastpage
    308
  • Abstract
    This paper discusses the design and development of a high-attenuation field-applicable acoustic enclosure for large power transformers, based in concept upon the "Field Incidence Mass Law" from the field of acoustics. Free-standing and form-fitting, enclosures of this type have been designed to provide noise reduction in the order of 15 to 20 db (decibels), in addition to other advantages inherent in a near-total enclosure.
  • Keywords
    Acoustic noise; Acoustical engineering; Advertising; Cities and towns; Costs; Low-frequency noise; Noise level; Noise reduction; Power engineering and energy; Power transformers;