DocumentCode
10276
Title
A Wideband Current Transformer Bridge
Author
Mohns, E. ; Meisner, J. ; Roeissle, Gunter ; Seckelmann, Michael
Author_Institution
Phys.-Tech. Bundesanstalt, Braunschweig, Germany
Volume
63
Issue
10
fYear
2014
fDate
Oct. 2014
Firstpage
2322
Lastpage
2329
Abstract
The development and testing results of a new current transformer (CT) test set at Physikalisch-Technische Bundesanstalt are described. The operation range for the ratio based bridge is intended for frequencies from 16.7 Hz up to 20 kHz. Equal setups of magnetically shielded current comparators with primary windings for rated currents from 100 mA up to 5 A convert the secondary currents of the standard CT and of the transformer under test (TUT) into proportional voltages. The errors of the TUT are calculated from the subsequent measurement of the complex voltage ratio. This current bridge and the voltage-ratio-based method allow comparing CTs with nonequal ratios. At 50 Hz, the measuring system offers an extended measurement uncertainty of less than 2 ppm or μrad, respectively. The bridge is verified for use with uncertainties of below 200 ppm or 400 μrad at a frequency of 20 kHz.
Keywords
bridge circuits; current comparators; current transformers; CT test set; Physikalisch-Technische Bundesanstalt; TUT; complex voltage ratio; current transformer test set; magnetically shielded current comparators; measurement uncertainty; primary windings; proportional voltages; transformer under test; wideband current transformer bridge; Bridge circuits; Current measurement; Magnetic cores; Magnetic noise; Magnetic shielding; Voltage measurement; Windings; Complex voltage ratio; current comparator (CC); current transformer (CT); magnetic shielding; two-channel sampling; two-channel sampling.;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/TIM.2014.2320835
Filename
6817614
Link To Document