Title :
The Shunt Tube Control of Thyratron Rectifiers
Author_Institution :
Member of the technical staff, power development group, Bell Telephone Laboratories, Inc., New York, N. Y.
Abstract :
The magnitude control of thyratrons in regulated rectifiers is accomplished effectively by the use of a shunt tube bridged across the d-c output and resistance coupled to the thyratron grids. The shunt tube grid operates from the output of a regulating feedback amplifier to give precision voltage regulation and highly improved dynamic response to transients, as well as electronic ripple suppression. Extensive application of this recent development has been made in supplying plate power to video and d-c amplifiers for radars and computers. Closely regulated d-c power for electronic equipment is not unduly costly when the shunt tube technique is applied.
Keywords :
Application software; Electron tubes; Electronic equipment; Feedback amplifiers; Power amplifiers; Power supplies; Radar applications; Rectifiers; Thyratrons; Voltage control;
Journal_Title :
American Institute of Electrical Engineers, Transactions of the
DOI :
10.1109/T-AIEE.1947.5059459