• DocumentCode
    1029678
  • Title

    DC ionised field quantities as influenced by coronating conductor surface gradient

  • Author

    Aboelsaad, M. ; Shafai, L.

  • Author_Institution
    University of Manitoba, Department of Electrical Engineering, Winnipeg, Canada
  • Volume
    23
  • Issue
    4
  • fYear
    1987
  • Firstpage
    162
  • Lastpage
    163
  • Abstract
    In unipolar DC corona, the assumption that the coronating conductor gradient is always constant at the onset value regardless of the level of the applied voltage has been repeatedly questioned in the literature. Rigorous assessment of the influence of his assumption on the ionised field quantities is the aim of the letter.
  • Keywords
    corona; current density; electric fields; DC ionised field quantities; coronating conductor surface gradient; current density; electric field intensity; unipolar DC corona;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • ISSN
    0013-5194
  • Type

    jour

  • DOI
    10.1049/el:19870115
  • Filename
    4257395