DocumentCode
1029678
Title
DC ionised field quantities as influenced by coronating conductor surface gradient
Author
Aboelsaad, M. ; Shafai, L.
Author_Institution
University of Manitoba, Department of Electrical Engineering, Winnipeg, Canada
Volume
23
Issue
4
fYear
1987
Firstpage
162
Lastpage
163
Abstract
In unipolar DC corona, the assumption that the coronating conductor gradient is always constant at the onset value regardless of the level of the applied voltage has been repeatedly questioned in the literature. Rigorous assessment of the influence of his assumption on the ionised field quantities is the aim of the letter.
Keywords
corona; current density; electric fields; DC ionised field quantities; coronating conductor surface gradient; current density; electric field intensity; unipolar DC corona;