DocumentCode :
1029694
Title :
The Development and Field Experience of a Transistor Electric Governor for Hydro Turbines
Author :
Leum, M.
Author_Institution :
Woodward Governor Co.
Issue :
4
fYear :
1966
fDate :
4/1/1966 12:00:00 AM
Firstpage :
393
Lastpage :
402
Abstract :
The general design requirement for an electric-hydraulic governing system for hydraulic turbines is that it must sense speed electrically, produce a signal suitable for control, and use this signal to position the gate servomotors. It must be capable of performing all auxiliary functions previously required plus some desirable new ones, such as joint control. The dead band must be less than 0.01 percent and the dead time less than 0.25 second. Its selling price should be equal to, or less than, mechanical governors. Its transient response characteristics must be excellent. The paper discusses how some of these goals have been met and presents results from field and shop tests.
Keywords :
Control systems; Diesel engines; Hydraulic turbines; Servomotors; Shafts; Signal design; Signal generators; Testing; Transducers; Transient response;
fLanguage :
English
Journal_Title :
Power Apparatus and Systems, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9510
Type :
jour
DOI :
10.1109/TPAS.1966.291577
Filename :
4073048
Link To Document :
بازگشت