DocumentCode
1030544
Title
Precision microwave measurement of the internal parasitics of tunnel-diodes
Author
Bandler, J.W.
Author_Institution
University of Manitoba, Winnipeg, Canada
Volume
15
Issue
5
fYear
1968
fDate
5/1/1968 12:00:00 AM
Firstpage
275
Lastpage
282
Abstract
This paper reports the results of precision microwave standing-wave measurements using a superheterodyne technique from 4 to 11 GHz on the internal parasitics of tunnel-diodes terminating a coaxial-line. Because of past conflicting conjectures as to the frequency dependence of the series resistance, particular attention has been paid to its accurate evaluation. Errors due to transmission-line attenuation and mount discontinuities have been explicitly eliminated from the measured results. The frequency invariance of the series inductance and junction capacitance is verified; but a new variation of series resistance with frequency is proposed of the form
, in accordance with the experimental results. The effect of this variation on the resistive cutoff frequency is discussed and a comparison is made With the relevant results of other researchers.
, in accordance with the experimental results. The effect of this variation on the resistive cutoff frequency is discussed and a comparison is made With the relevant results of other researchers.Keywords
Attenuation measurement; Capacitance; Coaxial components; Cutoff frequency; Electrical resistance measurement; Frequency dependence; Inductance; Microwave measurements; Microwave theory and techniques; Transmission lines;
fLanguage
English