• DocumentCode
    1030867
  • Title

    Multiple-source, multiple-frequency error of an electric field meter

  • Author

    Randa, J. ; Kanda, Motohisa

  • Author_Institution
    National Bureau of Standards, Boulder, CO, USA
  • Volume
    33
  • Issue
    1
  • fYear
    1985
  • fDate
    1/1/1985 12:00:00 AM
  • Firstpage
    2
  • Lastpage
    9
  • Abstract
    Electric field meters (EFM´s) are typically calibrated using single-frequency, single-source standard fields. The response to multiple sources or nonsinusoidal time dependence may be different, however. Possible errors in a multiple-source, multiple-frequency environment are analyzed for an EFM consisting of an electrically short dipole antenna with a diode load and a radio-frequency (RF) filter transmission line. Also considered are errors in the assumption of equal electric and magnetic energy densities in a multiple plane-wave environment. Typical errors of field-intensity measurements are about one to 3 dB, but in some circumstances they can exceed 10 dB.
  • Keywords
    Dipole antennas; Electromagnetic (EM) measurements; Electromagnetic interference (EMI); Probe antennas; Antenna measurements; Diodes; Dipole antennas; Filters; Loaded antennas; Magnetic analysis; Magnetic separation; Radio frequency; Transmission line antennas; Transmission line measurements;
  • fLanguage
    English
  • Journal_Title
    Antennas and Propagation, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-926X
  • Type

    jour

  • DOI
    10.1109/TAP.1985.1143461
  • Filename