DocumentCode :
1031531
Title :
Application of the Vibration Decay Test to Transmission Line Conductors
Author :
Hard, A.R. ; Holben, R.D.
Author_Institution :
Head of Vibration Research, College of Engineering, Research Division, Washington State University
Issue :
2
fYear :
1967
Firstpage :
189
Lastpage :
199
Abstract :
Application of the vibration decay test to transmission line conductors provides a simple method of evaluating conductor self-damping on laboratory spans. Although special recording methods are not necessary, logarithmic response recorders simplify the data reduction. The procedure can be used to investigate the effects of stringing tension, external damping, and conductor history on conductor self-damping. The prime advantage of the decrement procedure is its simplicity and the ease of data reduction.
Keywords :
Conductors; Corona; Electric breakdown; Gases; Nitrogen; Power supplies; Power transmission lines; Sparks; Testing; Transmission lines;
fLanguage :
English
Journal_Title :
Power Apparatus and Systems, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9510
Type :
jour
DOI :
10.1109/TPAS.1967.291835
Filename :
4073259
Link To Document :
بازگشت