Earth Fault Clearing on an HV DC Transmission Line, with Special Consideration of the Properties of the DC Arc in Free Air
Author :
Kohler, A.
Author_Institution :
Allmÿnna Svenska Elektriska Aktiebolaget
Issue :
3
fYear :
1967
fDate :
3/1/1967 12:00:00 AM
Firstpage :
298
Lastpage :
304
Abstract :
For the design and sensitivity setting of dc line earth fault protection of HV dc transmission lines it is necessary to know the properties of a free burning dc arc. On a dc line such an arc is most probably initiated by an atmospheric over-voltage. The most important properties of the arc are the arc voltage and the deionization time.
Keywords :
Earth; Fuses; Inverters; Power transmission lines; Protection; Rectifiers; System testing; Transmission lines; Voltage; Wire;