DocumentCode :
1032511
Title :
Life tests on vacuum switches breaking 50 kA unidirectional current
Author :
Benfatto, I. ; De Lorenzi, A. ; Maschio, A. ; Weigand, W. ; Timmert, H.P. ; Weyer, H.
Author_Institution :
Istituto Gas Ionizzati, Padova, Italy
Volume :
6
Issue :
2
fYear :
1991
fDate :
4/1/1991 12:00:00 AM
Firstpage :
824
Lastpage :
832
Abstract :
The results of two different series of life tests carried out on vacuum switches with a self-produced axial magnetic field (in view of their use in nuclear fusion facilities) are presented. The goal was to obtain a large number (on the order of 2000) of interruptions of a unidirectional current of over 50 kA, with a recovery voltage of up to 35 kV. A first series of tests showed that the test procedure with an accelerated life test was not adequate; it was also apparent that the contact plate, designed for 50 Hz applications, had weak points when subjected to extended thermal contacts. Therefore, a new version of the switches, with modified contacts, was built. Both versions of the switches were tested with a new test procedure, and satisfactory test results were obtained
Keywords :
life testing; switchgear; vacuum apparatus; 35 kV; 50 kA; life testing; recovery voltage; self-produced axial magnetic field; thermal contacts; unidirectional current; vacuum switches; Automatic testing; Energy exchange; Fusion reactors; Life testing; Magnetic fields; Magnetic switching; Switches; Thermal stresses; Variable structure systems; Voltage;
fLanguage :
English
Journal_Title :
Power Delivery, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-8977
Type :
jour
DOI :
10.1109/61.131141
Filename :
131141
Link To Document :
بازگشت