• DocumentCode
    1033530
  • Title

    Initial performance of the Wire Imaging Synchrotron Radiation Detector

  • Author

    von Zanthier, C. ; Gomez Cadenas, J.J. ; Kent, J. ; King, M. ; Watson, S. ; Briggs, D.D. ; Rouse, F. ; Tinsman, J.

  • Author_Institution
    California Univ., Santa Cruz, CA, USA
  • Volume
    37
  • Issue
    2
  • fYear
    1990
  • fDate
    4/1/1990 12:00:00 AM
  • Firstpage
    44
  • Lastpage
    47
  • Abstract
    The initial performance of a novel detector (called the Wire Imaging Synchrotron Radiation Detector) that measures the positions of intense synchrotron-radiation beams with high precision is described. Two detectors of this kind are used for the precision energy spectrometers of the Stanford Linear Collider (SLC). The detectors accurately determine the distance between pairs of intense synchrotron beams of typically 1-MeV photons, which are emitted by the primary electron and positron beams of the SLC. The detectors intercept the synchrotron beams with arrays of fine wires. The ejection of Compton-recoil electrons leaves positive charges on the wires, enabling a determination of beam positions. Preliminary measurements indicate that it is possible to determine the synchrotron stripe positions to better than 25 μm
  • Keywords
    X-ray detection and measurement; particle beam diagnostics; particle detectors; Compton-recoil electrons; Stanford Linear Collider; Wire Imaging Synchrotron Radiation Detector; intense synchrotron-radiation beams; precision energy spectrometers; Collimators; Electron beams; Magnetic separation; Position measurement; Positrons; Radiation detectors; Sensor arrays; Spectroscopy; Synchrotron radiation; Wire;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.106589
  • Filename