• DocumentCode
    1034210
  • Title

    Zero average current error controlled power flow for AC-DC power converters

  • Author

    Borle, Lawrence J. ; Nayar, Chemmangot V.

  • Author_Institution
    Adv. Energy Syst. Ltd., Bentley, WA, USA
  • Volume
    10
  • Issue
    6
  • fYear
    1995
  • fDate
    11/1/1995 12:00:00 AM
  • Firstpage
    725
  • Lastpage
    732
  • Abstract
    Unity and controlled power factor AC-DC power converters require a current control technique with zero average current error (ZACE) in each switching period. Acting on the current error signal alone, a ZACE controlled converter offers complete real and reactive power flow control with negligible low order current harmonics, a narrow switching frequency band, and relative immunity to DC link or AC line voltage harmonics. Slope-generated hysteresis, a new ZACE current control method is introduced. Simulation and experimental results in a three phase converter are presented
  • Keywords
    AC-DC power convertors; electric current control; power factor correction; reactive power control; switching circuits; AC line voltage harmonics immunity; AC-DC power converters; DC link harmonics immunity; controlled power factor; narrow switching frequency band; reactive power flow control; real power flow control; slope-generated hysteresis; three phase converter; unity power factor; zero average current error; AC-DC power converters; Analog-digital conversion; Current control; Error correction; Load flow; Power system harmonics; Reactive power; Reactive power control; Switching converters; Voltage control;
  • fLanguage
    English
  • Journal_Title
    Power Electronics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8993
  • Type

    jour

  • DOI
    10.1109/63.471292
  • Filename
    471292