DocumentCode :
1034388
Title :
Power system frequency deviation measurement using an electronic bridge
Author :
Ahmad, Mukhtar
Author_Institution :
Dept. of Electr. Eng., Aligarh Muslim Univ., India
Volume :
37
Issue :
1
fYear :
1988
fDate :
3/1/1988 12:00:00 AM
Firstpage :
147
Lastpage :
148
Abstract :
A very simple frequency-deviation measuring instrument that works on the principle of a two-arm bridge is described. The circuit was fabricated and tested in the laboratory. The results indicate good linearity between frequency deviation and voltage or pulse count over the normal range of power system frequencies. The same instrument along with a variable frequency supply can also be used to measure a capacitance or a resistance
Keywords :
bridge circuits; bridge instruments; frequency measurement; power system measurement; capacitance measurement; electronic bridge; frequency-deviation measuring instrument; linearity; power system measurement; resistance measurement; two-arm bridge; Bridge circuits; Circuit testing; Frequency measurement; Instruments; Laboratories; Linearity; Power measurement; Power system measurements; Pulse power systems; Voltage;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/19.2685
Filename :
2685
Link To Document :
بازگشت