DocumentCode
1035560
Title
An analytic model for the fluxgate magnetometer
Author
Marshall, Stanley V.
Author_Institution
University of Missouri, Rolla, Mo
Volume
3
Issue
3
fYear
1967
fDate
9/1/1967 12:00:00 AM
Firstpage
459
Lastpage
463
Abstract
The output voltages from various fluxgate probe types are found to have the same general form, and an analytic model has been developed with which the output may be calculated. In the saturation region where the output pulse is developed, the differential permeability can be closely approximated by an exponential,
, where k1 and k2 are on the order of 100 and -2.0, respectively, for cores of Supermalloy or Permalloy 80. Using this model, the effect of the nature of the excitation function on output pulse amplitude and width and the effect of the squareness of the core characteristic can be clearly demonstrated, and good agreement with experimental results has been obtained.
, where kKeywords
Magnetometers; Filtering; Geophysical measurements; Magnetic analysis; Magnetic field measurement; Magnetometers; Power harmonic filters; Probes; Voltage; Wire; Wounds;