DocumentCode
1036185
Title
Transient Response or Direct-Current Dynamos
Author
Koenig, H.E.
Author_Institution
University of Illinois, Urbana, Ill.
Volume
69
Issue
1
fYear
1950
Firstpage
139
Lastpage
145
Abstract
Equations for the transient current of both the armature and field of a d-c shunt-wound machine are developed. The equations are derived from the theorem of constant flux linkages and in terms of the mutual inductance between the armature and shunt field. Methods for measuring this mutual inductance as well as other constants of the machine are developed. It is believed that the analysis can be extended to include almost any type of d-c dynamo, including the amplidyne. The results obtained from the theoretical analysis are in agreement with experimental data.
Keywords
Armature; Brushes; Commutation; Couplings; Equations; Magnetohydrodynamic power generation; Synchronous machines; Transient analysis; Transient response; Voltage;
fLanguage
English
Journal_Title
American Institute of Electrical Engineers, Transactions of the
Publisher
ieee
ISSN
0096-3860
Type
jour
DOI
10.1109/T-AIEE.1950.5060132
Filename
5060132
Link To Document