• DocumentCode
    1037026
  • Title

    A Direct Reading High-Voltage Capacitanice Bridge

  • Author

    Foley, A.H.

  • Author_Institution
    General Electric Company, Pittsfield, Mass.
  • Volume
    69
  • Issue
    2
  • fYear
    1950
  • Firstpage
    692
  • Lastpage
    698
  • Abstract
    In contrast with the conventional Schering bridge, the network described in this paper is direct reading for both dissipation factor and capacitance, has a fixed guard adjustment, and hence simplified operation. A unique method of phase-angle compensation employs adjustment of the effective phase angle of the standard capacitor. This compensation may be either positive or negative as required. Design is simplified since compensation for stray wiring capacitances is easily accomplished. Simplified operation and elimination of all calculations permit substantial reductions in unit testing time and operation by nontechnical personnel without sacrifice of accuracy.
  • Keywords
    Bridge circuits; Capacitance measurement; Capacitors; Circuit testing; Frequency; Packaging; Personnel; Production; Voltage; Wiring;
  • fLanguage
    English
  • Journal_Title
    American Institute of Electrical Engineers, Transactions of the
  • Publisher
    ieee
  • ISSN
    0096-3860
  • Type

    jour

  • DOI
    10.1109/T-AIEE.1950.5060212
  • Filename
    5060212