DocumentCode
1037026
Title
A Direct Reading High-Voltage Capacitanice Bridge
Author
Foley, A.H.
Author_Institution
General Electric Company, Pittsfield, Mass.
Volume
69
Issue
2
fYear
1950
Firstpage
692
Lastpage
698
Abstract
In contrast with the conventional Schering bridge, the network described in this paper is direct reading for both dissipation factor and capacitance, has a fixed guard adjustment, and hence simplified operation. A unique method of phase-angle compensation employs adjustment of the effective phase angle of the standard capacitor. This compensation may be either positive or negative as required. Design is simplified since compensation for stray wiring capacitances is easily accomplished. Simplified operation and elimination of all calculations permit substantial reductions in unit testing time and operation by nontechnical personnel without sacrifice of accuracy.
Keywords
Bridge circuits; Capacitance measurement; Capacitors; Circuit testing; Frequency; Packaging; Personnel; Production; Voltage; Wiring;
fLanguage
English
Journal_Title
American Institute of Electrical Engineers, Transactions of the
Publisher
ieee
ISSN
0096-3860
Type
jour
DOI
10.1109/T-AIEE.1950.5060212
Filename