DocumentCode :
1038375
Title :
A loss measurement system in a test facility for high-current superconducting cables and wires
Author :
Roovers, A.J.M. ; Uijttewaal, W. ; Kate, H. H J Ten ; Haken, B. Ten ; van de Klundert, L.J.M.
Author_Institution :
Dept. of Appl. Phys., Twente Univ., Enschede, Netherlands
Volume :
24
Issue :
2
fYear :
1988
fDate :
3/1/1988 12:00:00 AM
Firstpage :
1174
Lastpage :
1177
Abstract :
The AC loss measurement system in the Twente test facility is operational. Preliminary results of the first loss measurements on a vacuum-welded conductor are presented. The Twente test facility is a high-current system in which superconductors can be tested up to 7 T and 25 kA. The loss measurements were done on a monolith conductor designed for TORE SUPRA, manufactured by Vacuumschmelze.
Keywords :
loss measurement; magnetic variables measurement; superconducting cables; test facilities; 25 kA; AC loss measurement system; TORE SUPRA; high-current superconducting cables; monolith conductor; superconducting wires; test facility; vacuum-welded conductor; Conductors; Helium; Loss measurement; Magnetic field measurement; Magnetic separation; Superconducting cables; Superconducting coils; Superconductivity; System testing; Test facilities;
fLanguage :
English
Journal_Title :
Magnetics, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/20.11442
Filename :
11442
Link To Document :