Abstract :
Test performance of the primary terminator is described, and an analysis of fault-closure capability and load-break life is presented. It has been determined that fault-closure performance is a function of 1) instantaneous voltage at the point of closure, 2) speed of closure, and 3) condition of insulating surfaces separating the male and female contacts.
Keywords :
Acceleration; Circuits; Connectors; Contacts; Insulation; Performance analysis; Plugs; Testing; Velocity control; Voltage control;