Development of single drive electrode electrical resistance tomography system
Author
Dong, Feng ; Tan, Chao ; Liu, Junwen ; Xu, Yanbin ; Wang, Huaxiang
Author_Institution
Sch. of Electr. Eng. & Autom., Tianjin Univ., China
Volume
55
Issue
4
fYear
2006
Firstpage
1208
Lastpage
1214
Abstract
A new electrical resistance tomography system has been designed using the single drive electrode method. The bidirectional pulse current is adopted in this system as the exciting current. The model of this new method has been set up in ANSYS and validated by simulation and actual measured data. Based on this model, the influence of medium resistivity and connected resistance as well as the influence of medium distribution on the measured data is studied. The experimental results and the reconstructed images are presented at last to testify to the reliability of the new system and the feasibility of the new method.
Keywords
data acquisition; electric resistance measurement; electrochemical electrodes; image reconstruction; reliability; ANSYS; bidirectional pulse current; connected resistance; data acquisition strategy; electrical resistance tomography; exciting current; image reconstruction; medium distribution influence; medium resistivity; reliability; single drive electrode; Conductivity measurement; Current measurement; Data acquisition; Electric resistance; Electric variables measurement; Electrical resistance measurement; Electrodes; Hardware; Image reconstruction; Tomography; Bidirectional pulse current; data acquisition strategy; electrical resistance tomography; image reconstruction; single drive electrode method;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/TIM.2006.877751
Filename
1658373
Link To Document