• DocumentCode
    1039133
  • Title

    Unity power factor high current slew rate magnet power supply

  • Author

    Dawson, F.P.

  • Author_Institution
    Dept. of Electr. Eng., Toronto Univ., Ont., Canada
  • Volume
    25
  • Issue
    5
  • fYear
    1989
  • fDate
    9/1/1989 12:00:00 AM
  • Firstpage
    3985
  • Lastpage
    3987
  • Abstract
    The author presents an alternative design scheme which utilizes a conventional AC-to-DC n-pulse bridge and a DC-side commutation network. With the addition of a commutator, converter device latching current problems are overcome; a current slew rate can be preprogrammed within certain limitations; magnet current can be commutated safely in the event of a line voltage collapse; and the main converter can be designed to operate at rated load with a unity power factor. The major focus of the present work is to develop a simple analytical model of the converter commutator and magnet system suitable for design purposes. The model has been verified experimentally. Practical limitations of this circuit are described
  • Keywords
    electromagnets; power convertors; power factor; power supplies to apparatus; DC-side commutation network; analytical model; design; high current slew rate; latching current; line voltage collapse; magnet power supply; unity power factor; Bridge circuits; Plasma confinement; Power supplies; Pulsed power supplies; Reactive power; Switching converters; Thyristors; Toroidal magnetic fields; Voltage; Wire;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/20.42605
  • Filename
    42605