DocumentCode :
1041803
Title :
Investigation of corona discharge devices as electrical loads for experimental high-voltage generators
Author :
Josh, Krishan K. ; Maloney, Thomas H.
Author_Institution :
Systems Research Laboratories, Dayton, Ohio
Volume :
18
Issue :
12
fYear :
1971
fDate :
12/1/1971 12:00:00 AM
Firstpage :
1163
Lastpage :
1166
Abstract :
The use of the corona discharge mechanism as a means of providing an electrical load for experimental high-voltage low-current dc generators is investigated. The current-voltage characteristics of several corona discharge configurations, such as point-to-plane, coaxial cylindrical, and wire-to-plane, were experimentally obtained and compared with theoretically predicted values. Of all the configurations tested, the wire-to-plane configuration is found to be capable of dissipating the maximum electrical power (nearly 3 kW/m length of wire) and exhibits a wide range of current-voltage characteristics at various pressures, depending largely upon the wire-to-plane spacing.
Keywords :
Coaxial components; Corona; DC generators; Electrodes; Laboratories; Power generation; Sparks; Testing; Voltage; Wire;