The influence of high magnetic flux densities on electromagnetic focusing of electrons
Author
Johnson, C.B.
Volume
18
Issue
12
fYear
1971
fDate
12/1/1971 12:00:00 AM
Firstpage
1187
Lastpage
1188
Abstract
The resolution of "magnetically focused" image tubes is shown to be relatively constant with increasing magnetic flux density (B) until B exceeds (2/ηΔt), where η is the Electron charge-to-mass ratio and Δt is the transit-time, difference between focused and unfocused electrons. Magnetic flux densities higher than this value give rise to increased electron-optic resolutions, in proportion to B.
Keywords
Density measurement; Electrons; Lattices; Magnetic field measurement; Magnetic flux density; Magnetic noise; Noise measurement; Ohmic contacts; Temperature measurement; Voltage;