DocumentCode :
1042107
Title :
A ten-stage electrostatic depressed collector for improving klystron efficiency
Author :
Neugebauer, Wendell ; Mihran, Theodore G.
Author_Institution :
General Electric Company, Schenectady, N. Y.
Volume :
19
Issue :
1
fYear :
1972
fDate :
1/1/1972 12:00:00 AM
Firstpage :
111
Lastpage :
121
Abstract :
A ten-stage electrostatic depressed collector, designed with the aid of an analog computer, was tested on a 1-kW CW 750-MHz klystron. Excellent correlation was achieved between computed and measured performance under varying conditions of RF drive. At full RF power output approximately 60 percent of the spent beam energy was recovered by use of the depressed collector. The net power conversion efficiency of the tube was raised from its undepressed value of 54.3 percent to approximately 70.9 percent. At one-half full power output, a collector efficiency of 70 percent was measured. At zero RF power output collector efficiency was 80 percent. To achieve these results it was necessary to install a small focusing coil between the final drift tube and the collector. No spurious oscillations or instabilities were detected when collector depression was employed, nor was electron backstreaming increased significantly. Intentional short circuiting of adjacent collector electrode pairs was shown to cause only minor degradation in collector performance.
Keywords :
Analog computers; Circuits; Coils; Electrons; Electrostatic measurements; Klystrons; Power conversion; Power measurement; Radio frequency; Testing;
fLanguage :
English
Journal_Title :
Electron Devices, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9383
Type :
jour
DOI :
10.1109/T-ED.1972.17379
Filename :
1476850
Link To Document :
بازگشت