• DocumentCode
    1043770
  • Title

    Noise temperature variation with mount style

  • Author

    Guentzler, Ronald E.

  • Author_Institution
    Ohio Northern University, Ada, Ohio
  • Volume
    19
  • Issue
    9
  • fYear
    1972
  • fDate
    9/1/1972 12:00:00 AM
  • Firstpage
    1063
  • Lastpage
    1065
  • Abstract
    Noise temperatures in argon discharges at 1-20 torr in 0.63-cm inner radius tubes are presented. The noise temperatures measured at 147 MHz were dependent upon the noise-extracting electrode arrangements; this dependence resulted from a radial noise temperature variation within the discharges. The radial variation is expected to cause a frequency dependence in the microwave region.
  • Keywords
    Argon; Electrodes; Electron tubes; Frequency dependence; Noise measurement; Temperature dependence; Temperature measurement;
  • fLanguage
    English
  • Journal_Title
    Electron Devices, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9383
  • Type

    jour

  • DOI
    10.1109/T-ED.1972.17546
  • Filename
    1477017