DocumentCode :
1044505
Title :
A Copper/Polyimide Fabrication Process for Fabricating High-Inductance Microinductor
Author :
Gao, Xiao-Yu ; Zhou, Yong ; Cao, Ying ; Lei, Chong ; Ding, Wen ; Choi, Hyung ; Won, Jonghwa
Author_Institution :
Shanghai Jiao Tong Univ., Shanghai
Volume :
30
Issue :
2
fYear :
2007
fDate :
4/1/2007 12:00:00 AM
Firstpage :
123
Lastpage :
127
Abstract :
This paper reports on a technological process that combines copper as conductor, permalloy as magnetic core material, and polyimide as insulation material to complete a microinductor on glass with high inductance. The shape of the magnetic core scheme was rectangular, of which the width of the long side and short side were 1.4 and 0.6 mm, respectively. The dimensions of the inductor are 3.86 mm times 3.94 mm times 90 mum with coil width of 20 mum and space of 35 mum. The results show that the maximum inductance is 4 muH at 1 MHz, and the maximum quality factor (Q-factor) is 1.5 at 2 MHz.
Keywords :
Permalloy; conductors (electric); inductance; inductors; magnetic cores; coil; conductor; copper/polyimide fabrication; high inductance; high-inductance microinductor; insulation material; magnetic core material; permalloy; Conducting materials; Copper; Fabrication; Glass; Inductance; Insulation; Magnetic cores; Magnetic materials; Polyimides; Q factor; High inductance; magnetic core; microinductor; quality factor;
fLanguage :
English
Journal_Title :
Electronics Packaging Manufacturing, IEEE Transactions on
Publisher :
ieee
ISSN :
1521-334X
Type :
jour
DOI :
10.1109/TEPM.2007.899134