DocumentCode :
10462
Title :
Alternatives for Helium-3 in Multiplicity Counters
Author :
Ely, James H. ; Siciliano, Edward R. ; Lintereur, Azaree T. ; Swinhoe, M.T.
Author_Institution :
Pacific Northwest Nat. Lab., Richland, WA, USA
Volume :
60
Issue :
2
fYear :
2013
fDate :
Apr-13
Firstpage :
510
Lastpage :
514
Abstract :
Alternatives to helium-3 are being actively pursued due to the shortage and rising costs of helium-3. For safeguards applications, there are a number of ongoing investigations to find alternatives that provide the same capability in a cost-effective manner. One of the greatest challenges is to find a comparable alternative for multiplicity counters, since they require high efficiency and short collection or die-away times. Work has been progressing on investigating three commercially available alternatives for high efficiency multiplicity counters: boron trifluoride (BF3) filled proportional tubes, boron-lined proportional tubes, and lithium fluoride with zinc sulfide coated light guides. The baseline multiplicity counter used for the investigation is the Epithermal Neutron Multiplicity Counter with 121 helium-3 filled tubes at 10 atmosphere pressure, which is a significant capability to match. The primary tool for the investigation has been modeling and simulation using the Monte Carlo N-Particle eXtended (MCNPX) radiation transport program, with experiments to validate the models. To directly calculate the coincidence rates in boron-lined (and possibly other) detectors, the MCNPX code has been enhanced to allow the existing coincidence tally to be used with energy deposition rather than neutron capture reactions. This allows boron-lined detectors to be modeled more accurately. Variations of tube number and diameter along with variations in the amount of inter-tube moderator have been conducted for the BF3 and boron-lined cases. Tube pressure was investigated for BF3 , up to two atmospheres, as well as optimal boron thickness in the boron-lined tubes. The lithium fluoride was modeled as sheets of material with light guides in between, and the number and thickness of the sheets investigated. The amount of light guide, which in this case doubles as a moderator, was also optimized. The results of these modeling and simulation optimiza- ion investigations are described and results presented.
Keywords :
Monte Carlo methods; boron compounds; helium-3 counters; BF3; BF3 filled proportional tubes; MCNPX radiation transport program; Monte Carlo N-Particle eXtended; baseline multiplicity counter; boron trifluoride; boron-lined detectors; boron-lined proportional tubes; boron-lined tubes; coincidence rates; cost-effective manner; die-away times; energy deposition; helium-3 alternatives; helium-3 filled tubes; high efficiency multiplicity counters; iEpithermal Neutron Multiplicity Counter; intertube moderator; lithium fluoride; neutron capture reactions; tube number; tube pressure; zinc sulfide coated light guides; Atmospheric modeling; Boron; Detectors; Electron tubes; Materials; Neutrons; Radiation detectors; Helium-3; multiplicity counters; neutron detection; safeguards;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2012.2227123
Filename :
6410457
Link To Document :
بازگشت