Abstract :
An original and reliable prototype injection setup has been developed in order to carry out accurate conducted susceptibility measurements up to 1.5 GHz. The prototype has been proposed as an alternative solution to typical injection setups such as a coupling capacitor, bias tee or cross-talk system, frequently used with the direct power injection standard IEC62132-4. Simple to build and mechanically sound, the prototype injection setup is used to merge continuous conducted electromagnetic disturbances with wanted signals by using merely a semi-rigid coaxial cable. It offers good stability on a wide frequency range. Furthermore, it is neither expensive nor complicated to build.
Keywords :
UHF integrated circuits; circuit stability; coaxial cables; electric admittance measurement; integrated circuit measurement; integrated circuit reliability; measurement uncertainty; radiofrequency interference; continuous conducted electromagnetic disturbances; integrated circuit susceptibility measurement accuracy; reliable prototype injection setup; semirigid coaxial cable; stability aspects;
fLanguage :
English
Journal_Title :
Science, Measurement & Technology, IET
Publisher :
iet
ISSN :
1751-8822
Type :
jour
DOI :
10.1049/iet-smt:20060142
Filename :
4267630
Link To Document :
بازگشت