DocumentCode :
1047349
Title :
Errors in the power loss measured in clockwise and anticlockwise rotational magnetisation. Part 1: Mathematical study
Author :
Zurek, S. ; Meydan, T.
Author_Institution :
Wolfson Centre for Magnetics, Cardiff Univ., UK
Volume :
153
Issue :
4
fYear :
2006
fDate :
7/7/2006 12:00:00 AM
Firstpage :
147
Lastpage :
151
Abstract :
It is well known that the rotational power loss differs if the flux vector is rotated in either a clockwise or an anticlockwise rotation direction. An analysis is presented that shows that averaging the clockwise and anticlockwise values introduces an additive error that is dependent on the angular misalignment between the measuring sensors. Equations to minimise this error are presented and validated by application to experiments on electrical sheet steel.
Keywords :
fluxgate magnetometers; loss measurement; magnetic sensors; magnetisation; power measurement; angular misalignment; anticlockwise rotational magnetization; clockwise rotational magnetization; electrical sheet steel; flux vector; power loss measurement; rotational power loss;
fLanguage :
English
Journal_Title :
Science, Measurement and Technology, IEE Proceedings -
Publisher :
iet
ISSN :
1350-2344
Type :
jour
DOI :
10.1049/ip-smt:20050072
Filename :
1659655
Link To Document :