• DocumentCode
    1047662
  • Title

    Test Method to Demonstrate the Seismic Capabilities of Equipment

  • Author

    Ferguson, W.H. ; Colaiaco, A.P. ; Fischer, E.G.

  • Author_Institution
    Westinghouse Electric Corporation
  • Issue
    5
  • fYear
    1972
  • Firstpage
    2026
  • Lastpage
    2031
  • Abstract
    A study of random motion effects reveals that broadband seismic disturbances become filtered by mechanical soil-structure systems to produce narrow-band floor response motion under the equipment. The latter corresponds to quasi-resonance vibration buildup at one or more natural frequencies of the building.
  • Keywords
    Buildings; Earthquakes; Electric shock; Floors; Frequency; Mathematical model; Motion analysis; Switchgear; Testing; Vibrations;
  • fLanguage
    English
  • Journal_Title
    Power Apparatus and Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9510
  • Type

    jour

  • DOI
    10.1109/TPAS.1972.293533
  • Filename